Page 80 - INTEGRITY windows and doors
P. 80

ALTITUDE GUIDELINE

Integrity® recommends the maximum altitude limitation for its seal insulated glass units. These limits do not account for
glass deflection which may take on a pillowed appearance below these elevations. The limits may be affected by site,
location, temperature and/or divided lites. Integrity does not recommend the use of IG units in excess of these specified
guidelines. These limitations apply to Integrity units and should not be interpreted as an industry standard.

ALL-ULTREX®                                                ALL-ULTREX

Casement                                                   Casement STC/OITC

ALTITUDE LIMITS (FEET)                                     ALTITUDE LIMITS (FEET)

     UNIT SIZE    1-6     2-0    2-6    3-0                UNIT SIZE        1-6      2-0    2-6    3-0

2-0  Annealed   4000    5000   6000   6000                 2-0  Annealed   3000    4000   4000   5000
     Tempered   6000    8000   10000  10000                     Tempered   5000    7000   8000   10000
                4000    6000   7000   8000                                 3000    4000   6000   6000
2-6  Annealed   7000    10000  10000  10000                2-6  Annealed   6000    8000   10000  10000
     Tempered   4000    6000   8000   9000                      Tempered   3000    5000   6000   8000
                8000    10000  10000  10000                                7000    10000  10000  10000
3-0  Annealed   4000    6000   8000   10000                3-0  Annealed   3000    5000   6000   8000
     Tempered   9000    10000  10000  10000                     Tempered   7000    10000  10000  10000
                4000    6000   8000   10000                                3000    5000   7000   8000
3-6  Annealed   9000    10000  10000  10000                3-6  Annealed   8000    10000  10000  10000
     Tempered   4000    6000   8000   10000                     Tempered   3000    5000   7000   9000
                10000   10000  10000  10000                                8000    10000  10000  10000
4-0  Annealed   4000    6000   8000   10000                4-0  Annealed   3000    5000   7000   9000
     Tempered   10000   10000  10000  10000                     Tempered   8000    10000  10000  10000
                4000    6000   8000   10000                                3000    5000   7000   9000
4-6  Annealed   10000   10000  10000  10000                4-6  Annealed   9000    10000  10000  10000
     Tempered   4000    6000   9000   10000                     Tempered   3000    5000   7000   9000
                10000   10000  10000  10000                                9000    10000  10000  10000
5-0  Annealed                                              5-0  Annealed
     Tempered                                                   Tempered

5-6  Annealed                                              5-6  Annealed
     Tempered                                                   Tempered

6-0  Annealed                                              6-0  Annealed
     Tempered                                                   Tempered

ALL-ULTREX                                                 ALL-ULTREX

Awning                                                     Awning STC/OITC

ALTITUDE LIMITS (FEET)                                     ALTITUDE LIMITS (FEET)

UNIT SIZE       1-6       2-0    2-6    3-0    3-6    4-0       UNIT SIZE  1-6       2-0    2-6    3-0    3-6    4-0

1-6  Annealed   4000    4000   4000   4000   4000   4000   1-6  Annealed   3000    3000   3000   3000   3000   3000
     Tempered   5000    6000   7000   8000   9000   9000        Tempered   4000    5000   6000   7000   7000   8000
                4000    5000   6000   6000   6000   6000                   3000    4000   4000   5000   5000   5000
2-0  Annealed   6000    8000   10000  10000  10000  10000  2-0  Annealed   5000    7000   8000   10000  10000  10000
     Tempered   4000    6000   7000   8000   8000   8000        Tempered   3000    4000   6000   6000   6000   7000
                7000    10000  10000  10000  10000  10000                  6000    8000   10000  10000  10000  10000
2-6  Annealed   4000    6000   8000   9000   10000  10000  2-6  Annealed   3000    5000   6000   8000   8000   8000
     Tempered   8000    10000  10000  10000  10000  10000       Tempered   7000    10000  10000  10000  10000  10000

3-0  Annealed                                              3-0  Annealed
     Tempered                                                   Tempered

Integrity Windows and Doors provides these elevation guidelines as a convenience to our customers. Integrity does not recommend installation above the elevation guidelines, and products installed above such elevations are not
warranted. A variety of factors, including ambient temperature, altitude, and other conditions outside Integrity’s control may cause glass deflection, distortion, or an increase in convexity of the insulating glass units. Deflection,
distortion, and increased convexity are not considered product defects and are not covered under Integrity’s general warranty; capillary tubes may minimize these effects. Integrity does not warrant the amount or percentage of
argon or other inert gas present in insulating glass at any time after manufacture. Inert gas dissipates over time, and may be ineffective in products manufactured with capillary tubes. Thermal efficiencies vary with the application
of the product. Integrity does not warrant that a specific level of thermal efficiency will be achieved by inert gas, low emissivity coatings, or other product features. Determining the suitability and compliance with local or other
applicable building codes or standards, of all building components, including the use of any Integrity product, and the design and installation of any flashing or sealing system, is the responsibility of the buyer, user, architect, contractor,
installer, and/or other construction professional. Integrity will not be liable for any problem or damage relating to inappropriate or faulty building design or construction, maintenance, installation, or selection of products. Integrity
does not warrant any product’s compliance with local or other applicable building codes or standards, or its suitability for use in connection with a project seeking third party certification to any standard.
80